From arrays to a sequence of events
A sensor frame, a controller output, and an applied mirror command are different events. Their ordering depends on exposure time, data availability, clock alignment, and actuator delay. A nominal frame rate cannot fill in missing timestamps.
Noether Replay reads the Adaptive Optics Telemetry (AOT) format, preserves available metadata, and checks whether the recording supports a consistent sequence. Calibration epochs are assigned only when they cover the complete exposure and its timing uncertainty.
What the software checks
- Event order: exposure, observation availability, controller completion, command issue, and actuator effect.
- Command provenance: which observation produced a command, and whether the record establishes that it was physically applied.
- Calibration: validity intervals, ambiguous epochs, and observations outside a calibration’s lifetime.
- Evidence integrity: exact array bytes, shapes, units, timing, and source metadata bound to the analysis.
- Noise conditioning: propagation of temporal and cross-channel covariance through filtered observation windows.
Inspectable examples
| Example | What it establishes |
|---|---|
| Synthetic event reconstruction | 72 known events, an omitted frame identifier, and four observations outside calibration validity. |
| Public PAPYRUS telemetry ↗ | Three 200-sample arrays imported. Missing event times prevent inference of an exact physical event sequence. |
| Correlated-noise example ↗ | In the declared synthetic AR(1) case, ignoring temporal correlation understates variance after averaging by 44.44%. |
Shadow policies can produce hypothetical commands from recorded observations. The measured outcomes still belong to the controller that generated the recording; they are not assigned to the shadow policy.
Why it matters for autonomy
Controller qualification starts with trustworthy measurements. Before testing a replacement policy, a team needs to know which commands reached the instrument, which calibration was valid, and whether a timing claim is supported by the record.
Noether Replay provides that offline foundation. It does not drive hardware, certify an instrument, or use a recording as proof of a different controller’s performance.